Berk zanjir uchun Om qonuni

Ampermetr va voltmetr yordamida berk zanjirdagi tok va kuchlanishni kuzatish

I = EYuK R + r
U = IR
Ur = Ir
Tok manbai
+
r = 1.0 Om
A
2.00 A
Kalit
R = 5  Om
V
10.00 V
I — tok yo'nalishi
Zanjir berk — ampermetr tokni, voltmetr kuchlanishni ko'rsatmoqda
EYuK = 12 V
R = 5 Om
r = 1.0 Om
Ampermetr ko'rsatkichi
I = 2.00 A
Voltmetr ko'rsatkichi
U = 10.00 V
Ichki kuchlanish tushuvi
Ur = 2.00 V
Umumiy qarshilik
Rum = 6.00 Om
1. Manba EYuK hosil qiladi
2. Ampermetr zanjirga ketma-ket ulanadi
3. Voltmetr R ga parallel ulanadi
4. I va U bir vaqtda o'lchanadi

Avtomatik hisoblash

I = EYuK R + r
I = 12 V ( 5 + 1.0 ) Om
U = IR = 2.00 × 5
Ampermetr: 2.00 A
Voltmetr: 10.00 V
Muhim: ampermetr zanjirga ketma-ket ulanadi, chunki u zanjirdan o'tayotgan tok kuchini o'lchaydi. Ideal ampermetrning qarshiligi juda kichik deb olinadi. Voltmetr esa R qarshilikka parallel ulanadi va uning uchlaridagi kuchlanishni o'lchaydi. Ideal voltmetrning qarshiligi juda katta deb olinadi. Kalit yopilganda ampermetr I = EYuK/(R+r) tok kuchini ko'rsatadi. Voltmetr esa U = IR kuchlanishni ko'rsatadi. Masalan, EYuK = 12 V, R = 5 Om va r = 1 Om bo'lsa, ampermetr 2 A, voltmetr esa 10 V ni ko'rsatadi.